198
RS-232C
(Sold separately.)
Baud rate
: Selectable from 1 200, 2 400, 4 800, 9 600,
19 200 and 38 400 bps.
Data bit length
: Selectable from 7 bit and 8 bit
Parity bit
: Selectable from None, Even and Odd number.
Stop bit
: Selectable from 1 bit and 2 bit
Terminator
: Selectable from CR + LF and CR
Communication method
: Half duplex
Synchronous method
: Start-stop synchronous method
Communication data
: ASCII code
RS-422/485
(Sold separately.)
Baud rate
: Selectable from 1 200, 2 400, 4 800, 9 600,
19 200 and 38 400 bps.
Data bit length
: Selectable from 7 bit and 8 bit
Parity bit
: Selectable from None, Even and Odd number.
Stop bit
: Selectable from 1 bit and 2 bit
Terminator
: Selectable from CR
+
LF and CR
Communication method
: Half duplex
Synchronous method
: Start-stop synchronous method
Address
: Selectable one from 0 to 31.
Transmission data
: ASCII code
Cable length
: Approx. 1 km
Connectable units
: 32 units at the maximum (RS-422
:
10 units)
Terminal resistance
: Internal
(Selects the presence by connection of terminal board.)
Input/output monitor with LED
Changeover the RS-422/485: Set by function.
Current output
(Sold separately.)
Output
: DC4 mA ~ 20 mA
Load resistance
: 510 ohm or less
Resoulution
: Approx.1/12 000 or more
Non-linearity
: 0.02 %F.S.
Over range
: Approx.DC2.4 mA at [
-
OL] display and
Approx.DC21.6 mA at [OL] display.
Output times
: 4 times/s, 20 times/s (Synchronous to display
times).
* An internal circuit and photo-coupler are insulated.
Effect due to temperature
Zero point
:
±
0.005 % F.S./
℃
Sensitivity
:
±
0.01 % F.S./
℃
Voltage output
(Sold separately.)
Output
: DC0 V ~ 10 V
Load resistance
: 5 k-ohm or more
Resoulution
: Approx.1/12 000 or more
Non-linearity
: 0.02 %F.S.
Over range
: Approx.DC
-
1 V at [
-
OL display and
Approx.DC11 V at [OL] display
Output times
: 4 times/s, 20 times/s (Synchronous to display
times)
* An internal circuit and photo-coupler are insulated.
Effect due to temperature
Zero point
:
±
0.015 % F.S./
℃
Sensitivity
:
±
0.015 % F.S./
℃
Summary of Contents for CSD-903-EX
Page 1: ...DIGITAL INDICATOR CSD 903 EX Instruction Manual EN294 1492 H ...
Page 2: ...IV ...
Page 91: ...75 ...
Page 93: ...77 ...
Page 95: ...79 ...
Page 97: ...81 ...
Page 199: ...183 Inform us about the contents of failure and situation at site in details ...
Page 204: ...188 Inform us about the contents of failure and situation at site in details ...
Page 206: ...190 Inform us about the contents of failure and situation at site in details ...
Page 209: ...193 Inform us about the contents of failure and situation at site in details ...
Page 224: ... ...
Page 225: ......