4-34
Setting Pump tube washing interval in Standby mode
Perform the pump tube washing periodically to prevent ink from clogging due to the coagulation of ink,
which occurs within the tube.
1
Select [ROUTINE SETUP] of the maintenance menu.
(1)
Press the
key in the local mode.
(2)
Select [MAINTENANCE] by pressing the
keys then press the
key.
(3)
Select [ROUTINE SETUP] by pressing the
keys.
(4)
Press the
key.
2
Select [PUMP TUBE WASH] by press-
ing the
keys.
3
Press the
key.
4
Set the tube washing interval by press-
ing the
keys.
•
Set value
: OFF, 1 - 168 hours
5
Press the
key.
6
Press the
key several times to end.
• This function is operable only under the condition that the machine is left in the following dis-
plays.
• When the cleaning solution has not been filled in the
machine, the right display is displayed at the step 5. Fill the
cleaning solution (
P.4-8) then redo the operations from
the step 1.
< L OCA L . 1 >
[ # 0 1 ]
* REMOT E . 1 *
[ # 0 1 ]
0 . 0 0m
LOCAL mode
REMOTE mode
ROU T I NE S E T UP
PUMP T UB E WA SH < e n t >
ROU T I NE S E T UP
WA SH I N T ERV A L
=
1
h
ROU T I NE S E T UP
WA SH I N T ERV A L
=
4
h
ROU T I NE S E T UP
PUMP T UB E WA SH < e n t >
* * Wa s h i n g L i q u i d * *
Summary of Contents for JV33-130BS
Page 1: ...MIMAKI ENGINEERING CO LTD URL http www mimaki co jp D201887 16 ...
Page 7: ...vi ...
Page 32: ...1 16 ...
Page 107: ...3 51 Machine settings 3 Convenient use 7 Press the key 8 Press the key several times to end ...
Page 154: ...Setting Routine operations 4 36 8 Press the key several times to end ...
Page 164: ...4 46 ...
Page 187: ...6 11 Function Flowchart 6 Appendix To P 6 12 To P 6 18 To P 6 24 To P 6 25 To P 6 26 ...
Page 191: ...6 15 Function Flowchart 6 Appendix ...
Page 203: ...Function Flowchart 6 27 6 Appendix Error is displayed I n k REP L Re p o r t PR I NT I NG ...
Page 204: ...6 28 ...
Page 205: ...D201887 16 10022012 ...