2-7
Setting the media
2
Basic Operations
On the absorption area
The absorption area of JF-1631 is shown in the following figure. Pressing
or
key, set the
optimum absorption area for the media to be set.
Size of the media and switch-over of the valve
When using fixed size media, set the suction valve and vacuum as follows:
• When changing the point of origin, please refer to P.3-2 .
Media size
Suction valve
Vacuum setting
F1
F2
F3
F4
R1
R2
FRONT
REAR
3 ' x 6 ' Board
Open
Open
Open
Open
Close
Close
ON
OFF
4 ' x 8 ' Board
Open
Open
Open
Open
Open
Close
ON
ON
5 ' x 10 ' Board
Open
Open
Open
Open
Open
Open
ON
ON
• When using the media other than the fixed length, open the suction valve corresponding to
the larger area than the size of the media.
FRONT
REAR
470
1010
1550
1850
2420
3100
920
1220
1600
▲
Mark
Use as a rough guide
for valve opening and
closing.
Origin
Seal indicating the point of origin
Provided at the 4 corners of the table.