For safe operation
WARNING
• Be sure to setup the appropriate air-moving system in case of using the device in a closed room or a
room with bad ventilation.
Cautions for constructing exhaust outlet
Please observe the following things to prevent the device.
(1)
The sharp of the exhaust outlet depends on your building enviroment. The exhouast outlet area is
required more than half of the duct entrance area.
(2)
If mounting a valve on the exhaust outlet, be sure to open the valve when using the device.
• The ink used for this device falls into the category of UN No.3082 and UN Class 9. Since the ink is
flammable, never use fire when using the device.
• When cleaning the ink station and head, be sure to wear the supplied goggle and gloves since you
may get ink or washing liquid in your eyes.
• If anyone drinks ink or washing liquid in mistake, get the person to vomit and see a doctor
immediately.Do not allow him or her drink vomit.Then, contact the Poison Control Center.
• If you absorb a lot of vapor and feel bad, immediately move to a location where fresh air is present
and then keep yourself warm and quiet.Then, consult a doctor as soon as possible.
• Discard the waste ink according to the local regulations of the area this unit is used.