4-44
Check the UV illumination intensity
1
Mount the sensor part of the illumination meter on the illumination
meter bracket.
(1)
Turn over the illumination meter bracket and insert the sensor into the guide part.
• Set it with the sensor hole faces downward so that the hole can be seen from the
obverse side of the bracket.
(2)
Insert the code between guides and then slide the sensor to the code side.
• Be sure to press the sensor part. Do not pull the code.
(3)
Turn the bracket to the obverse side and adjust the sensor hole to the center of the bracket
hole.
2
Select “UV lamp mode” from the maintenance menu.
(1)
Press the
key in the local mode.
(2)
Press the
to select [MAINTENANCE] and press the
key.
(3)
Press the
to select [UV LAMP] and press the
key.
(4)
Press the
to select [LEVEL CHECK] and press the
key.
(5)
Press the
key.
• The head wiping will be performed.
(6)
Press the
key.
• The carriage will move to the left rear part.
FUNCTION
ENTER
ENTER
ENTER
L E V E L CH E C K
W I P E S T A R T
: e n t
ENTER
L E V E L CH E C K
H E A D MOV E
: e n t
ENTER