4-45
Checking method of UV illumination intensity
4
Daily Maintenance
3
Mount the illumination meter bracket on the device.
(1)
Place the illumination meter bracket and the illumination meter on the left rear of the table.
• Adjust the rabbet for positioning the illumination meter bracket in order to match to the
corner of the adsorption board.
• Place the illumination meter in front of the illumination meter bracket.
• Be careful that the code does not loosen too much.
(2)
Using the Phillips screwdriver, fix the illumination meter bracket on the table with the
attached 2 screws (self-binding screw M5x10).
• Fix it using two guide holes located on
the backmost part.
4
Operate the switch of the illumination meter.
(1)
Turn the switch of the illumination meter to “H”.
(2)
Press the button of the left side several times to display
“DH MAX”.
(3)
Press the
key.
5
Measure the amount.
(1)
Press the
key.
(2)
When the checking of the measured value is
completed, press the
key.
(3)
Measure CH1 in the same manner.
(4)
Press the
key.
• Do not touch the illumination meter bracket during the check of illumination
intensity because it is heated by the UV lamp. You may suffer burns.
Illumination meter bracket
L E V E L CH E C K
S E T T H E T OO L
: e n t
ENTER
L E V E L CH E C K
CH 2 CH E C K S T A R T : e n t
ENTER
L E V E L CH E C K
CH K T H E T OO L
: e n t
ENTER
L E V E L CH E C K
CH 1 CH E C K S T A R T : e n t
L E V E L CH E C K
CH K T H E T OO L
: e n t
L E V E L CH E C K
E ND
: e n t
ENTER