![MIMAKI JF-1610 Operation Manual Download Page 117](http://html1.mh-extra.com/html/mimaki/jf-1610/jf-1610_operation-manual_1800229117.webp)
Before taking a phenomenon as a trouble
5-3
5
In
Cas
e of T
rouble
If image quality declines
Corrective measures against troubles in the case where satisfactory image quality is not provided are
described in this station.
Take measures in accordance with actual state of the picture.
If the measures fail restore the device to the normal state, contact your local MIMAKI distributor or MIMAKI
office call for service.
Resolving nozzle clogging
If nozzle clogging is not resolved even the head cleaning operation of P.2-10 has been executed, check the
following 2 items.
Fill ink with the operation of P.4-20.
Replace ink with the operation of P.4-4.
Stopping the unit during the operation
Press the EMERGENCY SWITCH for stopping the unit urgently
for the safety reason.
One EMERGENCY switch is placed on the front face of the unit
and 2 are placed on each of the back surface and Y-bar
respectively.
Development
Corrective measure
Lines/thin spots are obvious occur
(1)
Execute the head cleaning. (
P.2-10)
(2)
Clean the wiper and cap. (
P.4-26)
(3)
If slip of paper is present in the head path, for example,
above the work plate, remove it.
Large ink drop on media
(1)
Execute the ink caps cleaning. (
P.4-26)
(2)
Execute the head cleaning [normal]. (
P.2-10)
(3)
Dust the media.
(4)
Dust the table.
(5)
Execute the cleaning for the undersurface of the
carriage. P.4-8
(6)
Set a correct value to the head gap value.
P.3-7
Media is raised during printing and
printing stops.
*1
*1. During printing, media may be raised due to the heat from the UV lamp, causing printing to be stopped.
(1)
Set new media and start printing.
Summary of Contents for JF-1610
Page 32: ...1 14...
Page 48: ...2 16...
Page 68: ...3 20...
Page 128: ...6 6...
Page 140: ...6 18...
Page 141: ...D201645 20 29082008...
Page 142: ...NH FW 2 80 Printed in Japan MIMAKI ENGINEERING CO LTD 2008...