68
Pellerin Milnor Corporation
Figure 30.
Connection From Hydraulic Pump to Assist in Bearing Removal
Removing the Bearing Housing (Bearing and Seal Carrier),
Seal Sleeve, and Seals (Front or Rear)
BNWVUM02.T02 0000278618 A.4 A.5 A.3 3/12/20 11:54 AM Released
These procedures require the use of a pulling fixture and guide rods available from the Milnor
®
factory. With the bearing cover (or shaft seal holder) and the bearing removed, proceed as
follows:
1. Remove the three bearing housing cap bolts and the grease lines from the bearing housing
front plate. Install guide rods in two of the bolt holes, as shown in
2. Install the pulling fixture as shown in
, by placing each of the four threaded rods
through a hole in the steel plate with hexnuts to the outside of the plate then screwing each
rod into the appropriate tapped hole in the bearing housing (same holes as used to mount the
bearing cover or shaft seal holder).
Figure 31.
Two Bearing Housing Guide Rods
in Position
Figure 32.
Bearing Housing Pulling Fixture in
Position
Summary of Contents for 72044SR2
Page 2: ......
Page 9: ...1 General Service Safety Related Components Pellerin Milnor Corporation 7 ...
Page 112: ...110 Pellerin Milnor Corporation 4 Shell Cylinder Door ...
Page 113: ...This page intentionally blank ...
Page 128: ...126 Pellerin Milnor Corporation 5 Staph Guard ...
Page 129: ...This page intentionally blank ...
Page 135: ...6 Control Sensing Pellerin Milnor Corporation 133 ...
Page 147: ...7 Chemical Supply Devices Pellerin Milnor Corporation 145 ...
Page 149: ...This page intentionally blank ...
Page 157: ...8 Water Steam Pellerin Milnor Corporation 155 ...
Page 173: ...This page intentionally blank ...