Pellerin Milnor Corporation
99
Figure 50.
Ring Weldments
Shimming Ring Weldments
Reconnecting Ring Weldments
Legend
A...
Mounting bracket
B...
Shell (hanging free)
C...
Frame
D...
Shims
E...
Ring weldment
F...
2"
3. Stack shims on top of the ring weldment as required to make each gap
exactly 2 inches
as
shown in the left side of
Figure 50: Ring Weldments, page 99
. If the gap at any location is
less than 2 inches without shims, the shell must then be raised in the frame, using the proce-
dures previously described.
4. Once the proper arrangement of shims is made, remount the ring weldment and shims to the
mounting bracket (see the right side of
Figure 50: Ring Weldments, page 99
). Any extra
shims may be stacked on the top side of the mounting bracket plate to which the ring weld-
ment is attached.