PL-565
Accumass BW500
Page 85
Par
a
m
e
te
rs
Test and Diagnostic (P900 - P951)
These parameters are used for test and diagnostic purposes.
P900
Software Revision
Displays the EPROM (Flash ROM) software revision level.
P901
Memory Test
Tests the memory. Test is initiated by scrolling to the parameter or repeated by
'pressing enter'
Display:
PASS = normal
FAIL = consult Milltronics.
P911
mA Output Test
Tests the mA output value for the output selected, outputs 1 to 3 (P911 – 01 to -03)
Displays the value from the previous measurement. A test value can be entered and
the displayed value is transmitted to the output. Upon returning to the run mode, the
parameter assumes the actual mA output level.
(
f
=0)
Use the up and down to scroll the value
P914
mA Input Value
Displays the current mA input value for the input selected, inputs 1 to 2 (P914 – 01 to
-02).
Note:
Not applicable if mA I/O board is not connected.
P918
Speed Input Frequency
Displays the frequency of the speed input signal in Hertz.
P940
Load Cell mV Signal Test
Displays the raw (unbalanced) mV signal input for the selected load cell, load cells A
to D* (P940 – 01 to – 04)
Range 0.00 - 60.00 mV.
*depending on the number of load cells selected by P003, not all load cells may be in
use.
Summary of Contents for ACCUMASS BW500
Page 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Page 6: ...Page 6 Accumass BW500 PL 565...
Page 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Page 28: ...Page 28 Accumass BW500 PL 565 Installation...
Page 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Page 94: ...Page 94 Accumass BW500 PL 565 Operation...
Page 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Page 110: ...Page 110 Accumass BW500 PL 565 Batching...
Page 112: ...Page 112 Accumass BW500 PL 565 Certification...