Page 82
Accumass BW500
PL-565
Par
a
m
e
te
rs
P697
ECal Idler Spacing
Enters the measured distance between the weighing idlers. Refer to the associated
belt scale instruction manual.
(
f
=1.0)
Distance units are:
feet:
if the imperial system of measurement has been selected, P004 = 1
metres:
if the metric system of measurement has been selected, P004 = 2
Enter the distance to three decimal points.
P698
ECal Conveyor Inclination
Enters the inclination or declination angle of the conveyor at the point where the belt
scale is installed.
(
f
=0.0000)
Enter the inclination in degrees
Upon entry, display jumps to P017 to display the design load value as the test load.
P699
ECal mV Span
Applicable only for Milltronics belt scales not listed in P693, or scales other than
Milltronics (P693 = 4).
Enter the mV span corresponding to 0 to 100% full scale load
Upon entry, display jumps to P017 to display the design load value as the test load.
P735
Back Light
Sets the intensity of the back light for the LCD.
(
f
=10)
Entry:
0 = off
1 to 10 = low to high
Summary of Contents for ACCUMASS BW500
Page 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Page 6: ...Page 6 Accumass BW500 PL 565...
Page 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Page 28: ...Page 28 Accumass BW500 PL 565 Installation...
Page 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Page 94: ...Page 94 Accumass BW500 PL 565 Operation...
Page 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Page 110: ...Page 110 Accumass BW500 PL 565 Batching...
Page 112: ...Page 112 Accumass BW500 PL 565 Certification...