34
35
Analog Configuration file – PI PLASMA Standard
PI Plasma-DC with/without CWF - 10010602
Analog Configuration - 10010602 v1.02
PI Plasma-DC with/wihout CWF
10010602
Page 1 of 2
DIGITAL INPUTS (JMP1=Active-HIGH)
Pin# /
Military
Plug
Symbol
Name
Description
Active
1 / m
DIN15
!Quick-Stop
Emergency stop
When input is H the machine can operate.
When input is L the welding will stop instantly without slope
down and the machine cannot start welding; the CWF also
stops feeding without retract.
L
2 / n
DIN14
!Panel-Lock
Panel locking
When input is H machine and CWF panels can be operated.
When input is L panels are locked (panels can be unlocked
also using “User-Menu”).
L
3 / Z
DIN13
Pulse-Mode-Bit1
Current Pulse Mode Selection
Select current pulse mode based on inputs combination:
(Bit1)LL(Bit0)
No pulsation
(Bit1)LH(Bit0)
Slow-Pulse
(Bit1)HL(Bit0)
Fast-Pulse
(Bit1)HH(Bit0)
Synergic-Pulse
xx
4 / N
DIN12
Pulse-Mode-Bit0
5 / P
DIN11
Process-Selection
Welding Process Selection
When input is L selects TIG-DC process.
When input is H selects PLASMA-DC process.
H
6 / T
DIN10
Pilot-Trigger
Start Plasma Pilot Arc
When input is H and Plasma process is selected the pilot-arc
is turned ON. When input is L the pilot-arc is turned OFF.
Pilot-arc can be operated also during welding.
H
7 / C
DIN9
Program-Bit3
Welding Program Selection
Select program number based on inputs combination:
(Bit3)LLLL(Bit0)
Selected from machine
(Bit3)LLLH(Bit0)
Select program #1
(Bit3)LLHL(Bit0)
Select program #2
(Bit3)LLHH(Bit0)
Select program #3
…
(Bit3)HHHH(Bit0)
Select program #15
xxxx
8 / D
DIN8
Program-Bit2
9 / G
DIN7
Program-Bit1
10 / H
DIN6
Program-Bit0
11 / X
DIN5
Pulse-Wire
Enable CWF Wire Pulse*
When input is H the pulsation of wire is enabled according to
the CWF settings. If Slow-Pulse with correct timings (see user
manual) is enabled the wire-pulse is synchronized with
current.
H
12 / W
DIN4
Error-Reset
Active Errors Reset
When input makes a L-to-H transition all errors on PI, CWF
and interface are cleared. If errors are not clearable error
signals remain active.
H
13 / U
DIN3
Fwd-Wire-Inch
Forward Wire Inching*
When arc is off wire can be jogged forward from the CWF by
setting this input H.
H
14 / V
DIN2
Rev-Wire-Inch
Reverse Wire Inching*
When arc is off wire can be jogged backward in the CWF by
setting this input H.
H
15 / S
DIN1
Gas-Purge
Gas Purge Control
Set this input H to start Shield and Plasma Gas purge. This
input has no effects during welding.
H
16 / R
DIN0
Arc-Trigger
Start Welding Arc
When input is H welding is started (other tasks as wire-inch,
gas purge etc. are aborted).
If Quick-Stop is active arc is not started.
When input going H-to-L, the actual wire-speed is latched
disregarding the analogue value at the analog input.
H