36
37
Analog Configuration file – PI PLASMA Standard
PI Plasma-DC with/without CWF - 10010602
Analog Configuration - 10010602 v1.02
PI Plasma-DC with/wihout CWF
10010602
Page 2 of 2
DIGITAL OUTPUTS (JMP3=Active-HIGH)
Pin# /
Military
Plug
Symbol
Name
Description
Active
17 / d
DOUT0 Arc-Detect
Arc-Detect Status
Output is H when welding arc is present.
H
18 / j
DOUT1 Error-Shield-Gas
Shield Gas Error
Output is H when shield gas can not be maintained at set
level (i.e. low pressure, blocked pipes, etc.).
H
19 / k
DOUT2 Error-Plasma-Gas
Plasma Gas Error
Output is H when plasma gas can not be maintained at set
level (i.e. low pressure, blocked pipes, etc.).
H
20 / h
DOUT3 !Error
Global Error Status
Output is H when status is OK.
Output is L when some errors are active (interface, machine
or feeder).
L
21 / e
DOUT4 Pilot-Arc-Detect
Pilot-Arc-Detect Status
Output is H when pilot-arc is present.
H
ANALOG INPUTS
Pin# /
Military
Plug
Symbol
Name
Description
Range
25 / E
AIN0
Wire-Speed(+)
Set CWF Wire Speed*
Control CWF wire speed in real-time:
0V
0
m
/
min
; 10V
5
m
/
min
0-10V
26 / F
Wire-Speed(-)
27 / A
AIN1
Welding-C)
Set Welding Current
Control welding-current in real-time:
0V
0A ; 10V
500A
0-10V
28 / B
Welding-Current(-)
29 / f
AIN2
30 / g
ANALOG OUTPUTS
Pin# /
Military
Plug
Symbol
Name
Description
Range
31 / L
AOUT0 Welding-C)
Read Welding-Arc Current
Measure welding arc current in real-time:
0V
0A ; 10V
1000A
0-10V
32 / M
Welding-Current(-)
33 / J
AOUT1 Welding-V)
Read Welding-Arc Voltage
Measure welding arc voltage in real-time:
0V
0V ; 10V
100V
0-10V
34 / K
Welding-Voltage(-)
* Inputs working on selected CWF if present