This washer-extractor is fitted with an adapter for an external dispensing
system. The external pumps are controlled by relays in the washer-extractor.
The dispensing containers must be filled with the correct detergent or chemical
agents in the order specified.
Pre-
wash
Main wash
1st signal
Main wash
2nd signal
Finishing
Basic programmes
Cottons
R 1
R 2
R 5
R 4
Minimum iron
R 1
R 2
-
R 4
Delicates
R 3
R 3
-
R 4
Woollens
-
R 3
-
R 4
Quick wash
-
R 2
-
R 4
Intensive wash
-
R 2
-
R 4
R 1 = Relay 1 = Pre-wash
R 2 = Relay 2 = Main wash
R 3 = Relay 3 = Delicates / WetCare
R 4 = Relay 4 = Fabric softener / WetCare agent or surface disinfectant
*
R 5 = Relay 5 = Disinfecting agent or floor cleaning agent
*
R 6 = Relay 6 = Proofing agent
* When selecting the target group
Buildings maintenance
.
** Dispense when temperature is reached.
Relay control for external dispensing system