Malfunctions
58
Pictogram Meaning
Possible
cause
Remedy
Lower spray arm is
blocked
Spray arm is not correctly
engaged
Correctly engage the spray arm.
Spray arm obstructed by, e.g. a
piece of cutlery
Remove the obstruction.
Spray arm blocked by soiling
Clean the spray arm bearings
(
8.2).
Upper spray arm is
blocked
Spray arm obstructed by, e.g. high
dishes
Remove the obstruction.
Spray arm blocked by soiling
Clean the spray arm bearings
(
8.2).
Filter cylinder
blocked
Heavily contaminated filter cylinder
Remove, clean and replace the
filter cylinder.
Energy optimisation
1
On-site energy optimisation
equipment switches individual
electrical consumers (heating
elements).
Wait until the on-site energy
optimisation equipment switches
off.
Pump inlet filter not
fitted
Missing pump inlet filter
The machine switches off
after 30 seconds and will not
be filled.
Fit the pump inlet filter and, if
necessary, switch the machine on
again.
INFO:
When the prompt is
downgraded three times, the
machine can be switched on.
Pump inlet filter not
fitted despite three
prompts
Missing pump inlet filter
IMPORTANT:
The circulating
pump and drain pump may get
damaged by drawing in, for
example, pieces of cutlery.
Fit pump inlet filter.
Automatic hood
opening
2
defective.
Defective motor
Contact an authorised service
technician for the repair.
Tank will be filled
A wash programme is started
while the machine is refilling
Wait till the machine has been
filled.
Malfunction with
error code
Various
Display the error code (
9.1) and
assign the repair to an authorised
service technician.
1
is displayed only when the machine is connected to equipment with energy optimisation
2
Special equipment
Summary of Contents for PG 8172
Page 1: ...PG 8172 PG 8172 ECO PG 8172 l PG 8172 ECO ...
Page 3: ......
Page 39: ...Elektroanschluss 36 17 3 Anschlussschema ...
Page 79: ...Electrical connection 76 17 3 Connection diagram ...
Page 119: ...Raccordement électrique 116 17 3 Schéma de raccordement ...
Page 159: ...Collegamento elettrico 156 17 3 Schema di collegamento ...
Page 199: ...Elektrische aansluiting 196 17 3 Aansluitschema ...