Electrical connection
75
17.1 Connecting the mains cable
Requirements for the mains cable
Cable type: Type H07 RN-F or equivalent
Only for Canada: Mains cable must have AWG wiring.
The wires must be fitted with wire end ferrules.
Cross section and number of cores: suitable for on-site power and protection
for more information see the sticker in the front panel
Connect the mains
cable to the rear of the
machine.
Withdraw the mains
cable at the front and
route it to the left.
Follow the connection
diagram (
17.3).
Connect the wires of the
mains cable according
to the connection
diagram.
Close the quick release
connectors.
If necessary plug bridges.
Firmly press the bridges
with a screwdriver.
Connect the green-yellow
wire to the distributor of
the earth wires.
Attach the mains cable to
the mounting plate with a
cable tie for strain relief.
17.2 Establishing equi-potential bonding
Connect the machine into the on-site equipotential bonding system.
INFO
The terminal screw is located behind the right rear leg of the machine. It is identified with the
symbol.