Water connection
73
16 Water
connection
The water-related safety should be as per DIN EN 61770. The machine can be connected to an inlet water
supply without an intermediate connection to other safety equipment.
Warning
The machine and any other relevant additional devices must be connected in accordance with
standards and regulations.
INFO
At the commissioning of the machine the authorised service technician measures the water
hardness and saves it in the machine's electronic control unit.
16.1 Requirements for the on-site inlet water connection
Water quality
The fresh water must in microbiological aspects have the quality of drinking
water.
Water inlet temperature
PG 8172: max. 60 °C
PG 8172 ECO: Cold water (max. 20 °C)
Water hardness
3 °dH (3.8 °e, 5.34 °TH, 0.54 mmol/l, 3 gr/gal) (recommendation, to prevent
scaling of the machine)
30 °dH (37.6 °e, 53.4 °TH, 5.35 mmol/l, 30 gr/gal) with machines with an
internal water softener
PG 8172 ECO:
3 °dH (3.8 °e, 5.34 °TH, 0.54 mmol/l, 3 gr/gal) (recommendation, to prevent
scaling of the machine)
20 °dH (25.1 °e, 35.6 °TH, 3.58 mmol/l, 20 gr/gal) with machines with an
internal water softener
Connection of osmosis water is not permitted due to the copper pipes in the
waste air heat exchanger
Minimum flow pressure
PG 8172: 100 kPa (1.0 bar)
PG 8172 ECO: 150 kPa (1.5 bar)
Maximum inlet pressure
600 kPa (6.0 bar)
Flow rate
at least. 4 l/min
16.2 Requirements for the on-site water stopcock
easily
accessible
not behind the machine
3/4"
connector
1
16.3 Connecting the inlet hose
Caution
The inlet hose may not be shortened or damaged.
Old existing hoses may not be re-used.
Do not bend the inlet hose while laying it.
The inlet hose and water inlet filter are located in the machine.
INFO
The water inlet filter prevents particles from the water supply entering the machine thus preventing
extraneous rust on the cutlery and in the machine.
Right view
Connecting the inlet hose (TWw) to the machine.
Connect the water inlet filter to the on-site water stopcock.
Only with hot water connections in Great Britain:
Install the non-return valve between the water inlet filter and
the inlet hose. The non-return valve is located in a bag in the
machine.
Connect the inlet hose to the water inlet filter.
Open the water stopcock and test whether the connections are
tight.
1
For Canada: 3/4" connector with garden hose thread, male
GB
Summary of Contents for PG 8172
Page 1: ...PG 8172 PG 8172 ECO PG 8172 l PG 8172 ECO ...
Page 3: ......
Page 39: ...Elektroanschluss 36 17 3 Anschlussschema ...
Page 79: ...Electrical connection 76 17 3 Connection diagram ...
Page 119: ...Raccordement électrique 116 17 3 Schéma de raccordement ...
Page 159: ...Collegamento elettrico 156 17 3 Schema di collegamento ...
Page 199: ...Elektrische aansluiting 196 17 3 Aansluitschema ...