Changing the door hinges
83
Replace the panel
onto the soft-
close mechanism from above, click-
ing it back into place first at the bot-
tom and then at the top.
Close the upper machine door.
Reattaching the door handles
Risk of damage!
The door seal may be damaged if the
handle is fitted incorrectly.
Please make sure you follow the in-
structions below carefully when you
refit the handle.
Loosely attach the door handle to the
opposite side with the two front
screws
to start with.
The mounting plate
must be posi-
tioned on the door casing so that when
the door is closed it is flush with the
outer wall of the appliance.
Firmly tighten all 4 screws
.
From the appliance side, slide the
sidebar
into the guide on the
mounting plate until you hear it click
into place.
Make sure that the sidebar
does
not come into contact with the door
seal when the door is opened. This
would cause permanent damage to
the door seal.