Energy efficiency class
The energy efficiency class is calculated in accordance with EN 50304/EN 60350.
Energy efficiency class: A+
Please observe the following advice when testing:
– Use the Gentle bake
K
programme for testing purposes.
– Set the oven lighting to "On for 15 seconds" (see "Settings").
– Switch the catalyser off (see "Settings").
– During testing make sure that only those accessories required for the test are in
the oven cavity.
Do not use other accessories that might be available, such as FlexiClip runners
or catalytic enamelled panels such as side panels or roof liners.
– When calculating the Energy efficiency class it is important to keep the oven
door firmly closed.
Depending on test instruments used, the door seal function can be affected to
a greater or lesser degree. This can have a negative influence on test results.
This can be compensated for by pressing on the door. Where necessary
suitable technical measures can be used to assist. The door seal is not affected
in normal everyday use.
Product data sheets
The data sheets apply to ovens described in this operating instruction manual.
Note for test institutes
141