At the end of the activation phase
the
steam injection system will need to be
cleaned to remove all traces of
descaling solution.
Cleaning is carried out by flushing
approx. 1 litre of fresh tap water
through the system. The water is
collected in the universal tray. This
process is repeated three times.
A message will appear in the display
with advice about the rinsing process.
M
Take the universal tray out of the
oven and empty it. Place the tray
back in the oven again on the top
shelf level.
N
Detach the plastic tube from the
container.
O
Rinse the container and fill with
approx. 1 litre of fresh tap water.
P
Place the container back in the oven,
insert the plastic tube, secure it to
the container and close the door.
Q
Select "OK".
The intake process for the
first rinse
starts.
Water will be flushed through the steam
injection system and will then collect in
the universal tray.
A message will appear in the display
with advice about the
second rinsing
process
.
R
Take the universal tray out of the
oven and empty it. Place the tray
back in the oven again on the top
shelf level.
S
Detach the plastic tube from the
container. Fill it with approx. 1 litre of
fresh tap water.
T
Place the container back in the oven,
insert the plastic tube, secure it to
the container and close the door.
U
Select "OK".
V
Do the same for the
third rinsing
process
.
Leave the universal tray (with the
water which has collected in it) on the
top oven shelf whilst the evaporation
process takes place.
Cleaning and care