Technical Information
85
G 5xxx
Figure 050-11:
MPPW Circulation Pump Voltages
Note:
These voltages can also be measured when the pump is not activated.
2.12 Heater
Element
Water heating is carried out by a ring heater element in the circulation pump
housing. The heater element and circulation pump together form one
component. This ensures that on models with spray arm alternation heating
can always be carried out whichever water path is currently being used.
Integrating the heater element in the pump housing also ensures that it is
always cooled sufficiently thus preventing the baking-on of soil particles or
impurities in the water. The heater rating is 1.30 kilowatts at 120 volts.
Various safety measures protect the heater element against overheating,
such as the following:
Heater pressure switch
NTC temperature sensor
Electronic
control
The heater is activated only when the circulation pump has taken in sufficient water.
2.13
Heater Pressure Switch, B1/13
Heater pressure switch B1/13 is located directly on the circulation pump and
registers the water pressure when the pump is in operation.
Summary of Contents for Classic G 4205
Page 1: ...TECHNICAL INFORMATION G 5xxx Futura Dishwashers All US Models 2015 Miele USA ...
Page 32: ...Technical Information 32 G 5xxx 010 Casing ...
Page 39: ...Technical Information 39 G 5xxx 020 Door ...
Page 57: ...Technical Information 57 G 5xxx Figure 020 19 Drive ...
Page 58: ...Technical Information 58 G 5xxx 030 Front Panel ...
Page 64: ...Technical Information 64 G 5xxx 040 Inner Cabinet ...
Page 73: ...Technical Information 73 G 5xxx 050 Water Paths ...
Page 113: ...Technical Information 113 G 5xxx 080 Electronic Touchtronic Incognito Navitronic ...
Page 151: ...Technical Information 151 G 5xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...