Technical Information
101
G 5xxx
Warning!
MPPW circulation pump only:
When re-installing, it must be ensured that
the correct retaining screw is used for the pump mounting bracket as
otherwise the PCB could be damaged.
Warning!
Check seal placement for leakage issues, if needed.
Warning!
Installation aids that contain silicone, e.g., silicone grease, are not suitable
for use in dishwashers because of the damage they can cause.
If, e.g., hoses or seals are treated with silicone in order to facilitate
installation, this could jam the circulation pump. Furthermore, ingredients in
silicone grease can evaporate and damage electrical components such as
heater relays.
4.14
Removing the Circulation Pump Housing Cap with Ring Heater
Warning!
MPPW only:
In the open motor housing, there is an electronic module
circuit board (PCB) which must be protected from moisture and water
ingress in order to avoid short circuits.
1. Uninstall the appliance.
2. Disconnect the appliance from the power supply.
3. Remove the circulation pump; see Section 050-4.13.
4. Remove the retaining screws (see Figure 050-19, Item 8).
5. Push the retaining clips upwards (see Figure 050-19, Item 7).
6. Lightly twist the cap and pull it away from the housing to remove.
Figure 050-19:
Screws and Clips Securing the Pump Housing Cap (MPPW)
Summary of Contents for Classic G 4205
Page 1: ...TECHNICAL INFORMATION G 5xxx Futura Dishwashers All US Models 2015 Miele USA ...
Page 32: ...Technical Information 32 G 5xxx 010 Casing ...
Page 39: ...Technical Information 39 G 5xxx 020 Door ...
Page 57: ...Technical Information 57 G 5xxx Figure 020 19 Drive ...
Page 58: ...Technical Information 58 G 5xxx 030 Front Panel ...
Page 64: ...Technical Information 64 G 5xxx 040 Inner Cabinet ...
Page 73: ...Technical Information 73 G 5xxx 050 Water Paths ...
Page 113: ...Technical Information 113 G 5xxx 080 Electronic Touchtronic Incognito Navitronic ...
Page 151: ...Technical Information 151 G 5xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...