Technical Information
147
G 5xxx
Remedy:
Replace the circulation pump. See Section 050-4.13.
Cause:
Frequency converter electronic defective.
Remedy:
Replace the circulation pump. See Section 050-4.13.
3.35
Fault Code F79: Circulation Pump Interaction Fault
Symptom:
The program is interrupted and the drain pump is operated.
Cause:
Faulty interaction between the frequency converter electronic of the
circulation pump and the electronic (SLT).
Remedy:
1. Check for supply voltage.
a. Measure the voltage at the electronic (SLT) output and input.
b. Measure the voltage at the wiring harness.
c. Measure the voltage at the circulation pump.
2. Carry out appropriate remedial action (replacement of the electronic,
wiring harness or circulation pump).
Cause:
Frequency converter electronic defective.
Remedy:
Replace the circulation pump. See Section 050-4.13.
Cause:
Control electronic (SLT) defective.
Remedy:
Replace the control electronic. See Section 100-4.5 or 100-4.6.
3.36
Fault Code F84: Slide Shutter Positioning Fault
Symptom:
The program is interrupted and the drain pump is operated.
Cause:
Position switch defective.
Remedy:
Replace the circulation pump. See Section 050-4.13.
Cause:
Drive (synchronous motor) defective.
Remedy:
Replace the circulation pump. See Section 050-4.13.
Cause:
Slide shutter mechanism defective.
Summary of Contents for Classic G 4205
Page 1: ...TECHNICAL INFORMATION G 5xxx Futura Dishwashers All US Models 2015 Miele USA ...
Page 32: ...Technical Information 32 G 5xxx 010 Casing ...
Page 39: ...Technical Information 39 G 5xxx 020 Door ...
Page 57: ...Technical Information 57 G 5xxx Figure 020 19 Drive ...
Page 58: ...Technical Information 58 G 5xxx 030 Front Panel ...
Page 64: ...Technical Information 64 G 5xxx 040 Inner Cabinet ...
Page 73: ...Technical Information 73 G 5xxx 050 Water Paths ...
Page 113: ...Technical Information 113 G 5xxx 080 Electronic Touchtronic Incognito Navitronic ...
Page 151: ...Technical Information 151 G 5xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...