Technical Information
116
G 5xxx
arm position. After 0.7 gallons (2.7 liters) has been registered, the EGS
(electronically controlled water softener) valve is also opened until the
total desired intake quantity has been reached. The circulation pump with
switched auxiliary winding is then operated. At the same time the slide
shutter is activated with its setting alternating at 15-second intervals. After
a further 60 seconds, the heater relay is switched on for 300 seconds and
the water is heated to 122°F (50°C). The mini-program ends with 30
seconds drainage which begins with pulsed priming (2 seconds on/2
seconds off).
Note:
This mini-program does not include any fault-testing function.
2.
1K1
or
K1/1
, heater relay: The heater relay is activated for 60 seconds.
3.
M8
, drain pump: The drain pump is activated for 60 seconds.
4.
Y63, Y5,
water inlet valve with EGS valve (mini-program):
The water inlet valve is activated (on models with and without slide
shutter) until 1.4 gallons (5.4 liters) has been taken in. After 0.7 gallons
(2.7 liters) has been registered, the EGS valve is also opened until the
total desired intake quantity has been reached.
Warning!
If the flow meter is defective, the EGS valve will not be
activated.
5.
Y5
, EGS valve: The EGS valve is activated for 60 seconds. (Vacant in
models without EGS valve.)
6.
M6
, circulation pump auxiliary winding relay: The circulation pump with
switched auxiliary winding is activated. With a controlled circulation pump,
the activation is at the maximum speed for controlled operation. The
circulation pump is activated for 30 seconds but the auxiliary winding
relay is only activated during the first 15 seconds.
Note:
During the period when the auxiliary winding relay is activated, a
higher circulation pump current (approximately 0.9 amps) flows. After this
period, the current drops to approximately 0.16 amps.
Warning!
The circulation pump must not run for more than 30 seconds
without water.
7.
M24
,
M6
, slide shutter at middle spray arm setting with circulation pump:
The slide shutter is activated and set to the middle spray arm setting. The
circulation pump is then operated for 30 seconds at the maximum speed
for controlled operation. (MPEW and MPPW only.)
8.
M24, M6
, slide shutter at top/bottom spray arm setting with circulation
pump: The slide shutter is activated and set to the top/bottom spray arm
setting. The circulation pump is then operated for 30 seconds at the
maximum speed for controlled operation. (MPEW and MPPW only.)
9.
M24
, slide shutter: The slide shutter is activated for 60 seconds. (MPEW
and MPPW only.)
10.
Y50
, combination dispenser: The combination dispenser is activated with
Summary of Contents for Classic G 4205
Page 1: ...TECHNICAL INFORMATION G 5xxx Futura Dishwashers All US Models 2015 Miele USA ...
Page 32: ...Technical Information 32 G 5xxx 010 Casing ...
Page 39: ...Technical Information 39 G 5xxx 020 Door ...
Page 57: ...Technical Information 57 G 5xxx Figure 020 19 Drive ...
Page 58: ...Technical Information 58 G 5xxx 030 Front Panel ...
Page 64: ...Technical Information 64 G 5xxx 040 Inner Cabinet ...
Page 73: ...Technical Information 73 G 5xxx 050 Water Paths ...
Page 113: ...Technical Information 113 G 5xxx 080 Electronic Touchtronic Incognito Navitronic ...
Page 151: ...Technical Information 151 G 5xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...