Installation and user manual
D R Y 3 0 0 / 4 0 0 / 5 0 0 M e t a l / S i l v e r
V01/2022
|
4 4
6
TECHNICAL DATA
6.1
Technical data chart*
Data
Unit
DRY 300
METAL/
SILVER
DRY 400
METAL/
SILVER
DRY 500
METAL/
SILVER
For swimming pool with a max. water
surface of:
m
2
30
45
60
Dehumidification performance at 30°C
and 60% RV
l/24h
36
48
66
Dehumidification performance at 30°C
and 70% RV
l/24h
43
53
83
Dehumidification performance at 30°C
and 80% RV
l/24h
48
58
101
Standard operating temperature
°C
22-35
22-42
22-35
Operating temperature - defrost set
°C
15-35
15-42
15-35
Operating temperature - Thermostatic
expansion valve (TEV)
°C
22-42
-
22-42
Operating temperature - defrost set +
TEV
°C
15-42
-
15-42
Operating temperature - reverse defrost
°C
5-35
-
5-35
Operating hu range
% RV
20-100
20-100
20-100
Water flow
m
3
/h
550
600
800
Noise (at 1m distance)
dB (A)
42
42
44
Heating output
W
1900
1900
3500
El. input
W
700
700
1000
Power supply
V/Hz/f
230/50/1 230/50/1 230/50/1
Operating/starting current
A
3,1/15
3,1/15
4,5/15
El. insulation – type C
A
10
10
16
Power cord
mm2
CYSY 3C
x 1,5
CYSY 3C
x 1,5
CYSY 3C x
2,5
Condensing pipe - outer diameter
mm
d 20
d 20
d 20
Net dimensions (width x height x depth)
mm
780 x
642 x
300
780 x
642 x
300
1245 x
642x 300
Net weight
kg
50
50
77
Refrigerant quantity - R 410 A
kg
0,55;
1,15t CO
2
ekv.
0,6; 1,25t
CO
2
ekv.
0,75; 1,57
t CO
2
ekv.
Max. system pressure HP/LP
bar
28,5/8,5 28,5/8,5
28,5/8,5
* The manufacturer reserves the right to change the data without notice.
The refrigerant circuit is filled with R410A refrigerant, which is a two-component refrigerant (R32 / R125). These components
are in accordance with Act No. 286/2009 Coll. in conjunction with Regulation (EC) No 1049/2001 of the European Parliament
and of the Council 842/2006 considered as fluorinated greenhouse gases. The installations contain fluorinated greenhouse
gases covered by the Kyoto Protocol:
R410A with global warming potential (GWP) 2088:
(R-32/125 50/50)
These data are for information only. The exact amount of refrigerant in the appliance is indicated on the rating plate (located at
the back of the appliance in the upper right corner).
Summary of Contents for DRY 300
Page 46: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 6...
Page 47: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 7...
Page 48: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 8...
Page 50: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 0...
Page 51: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 1...
Page 53: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 3...
Page 54: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 4...
Page 55: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 5...
Page 58: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 8...
Page 63: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 3...
Page 64: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 4...
Page 65: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 5 Notes...
Page 66: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 6 Notes...
Page 67: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 7 Notes...