![MICROWELL DRY 300 Installation And User Manual Download Page 28](http://html1.mh-extra.com/html/microwell/dry-300/dry-300_installation-and-user-manual_1789810028.webp)
Installation and user manual
D R Y 3 0 0 / 4 0 0 / 5 0 0 M e t a l / S i l v e r
V01/2022
|
2 8
14.
Put the cover back on the device. Follow point 9 in reverse order.
15.
Switch on the circuit breaker to supply voltage to the dehumidifier's power supply. This turns on
the device. If you have set the fan to run continuously, it will turn on immediately. If the set
humidity is lower than the actual humidity, the compressor will also start after approx. 3 minutes.
You will hear a gentle vibration. Do not drain the dehumidifier without the main cover.
This
condition can cause back ventilation, virtually instant freezing of the device and damage.
16.
If the dehumidifier works properly, the installation is complete. If the pool hall has not yet been
completed, we recommend switching off the dehumidifier with a circuit breaker and wrapping the
dehumidifier in plastic foil. This will prevent dust and construction waste from entering the
device. More instructions in section 5.3. Condensed water drainage
5.3
Condensed water drainage
When drying your pool hall, your dehumidifier will condense the water that is fed into its internal
collection tray. Without active (free) condensate drainage, the dehumidification process will not
work. Condensation water is drained from the dehumidifier by gravity (downwards). The condensing
tray has the correct slope when the dehumidifier is mounted horizontally (using a spirit level).
Condensed water must be drained through a siphon to the sewer or to the outside environment.
Please do not place the drain hose upwards (against gravity), as this may cause the appliance to be
unable to drain water condensate. This in turn will cause water to leak from under the unit cover and
may lead to unit failure, damage, or failure. It can also cause the floor to get wet, creating the risk of
injury and damage to health from unwanted slipperiness. The manufacturer, distributor or dealer is
not liable for such damages. We recommend using the
HL 138
concealed siphon designed for air
conditioning units in the condensate drain. This must be located min. 20 cm below the condensate
outlet from the dehumidifier. The pictures below show more.
Warning:
Condensed water from the dehumidifier must not be collected in the collecting container
and drunk!
Condensed water from the dehumidifier must not be returned to the pool!
El. supply
Wall console
Drainage
Max. +/-0.3%
Preparation of electric power supply, condensate drain and console mounting
Summary of Contents for DRY 300
Page 46: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 6...
Page 47: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 7...
Page 48: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 8...
Page 50: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 0...
Page 51: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 1...
Page 53: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 3...
Page 54: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 4...
Page 55: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 5...
Page 58: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 8...
Page 63: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 3...
Page 64: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 4...
Page 65: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 5 Notes...
Page 66: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 6 Notes...
Page 67: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 7 Notes...