Installation and user manual
D R Y 3 0 0 / 4 0 0 / 5 0 0 M e t a l / S i l v e r
V01/2022
|
3 4
Electric heating element connection for DRY 300/400/500
5.4.3 Main electrical connection to the flexible cable to the electrical outlet
Models with a mobile stand on the floor are supplied with a flex cord for connecting a socket up to
220-240 V / 50 Hz / 1f. The socket must be designed for humid environments and separately
protected: a 16A circuit breaker (DRY 300/400/500) with a residual current device (RCD) with a
rated residual current not exceeding 30 mA.
After placing the dehumidifier with the mobile stand to the place of use, it is necessary to secure the
2 wheels on the front of the mobile stand against movement according to the following picture:
Mobile Stand
Your dehumidifier can be used on a mobile stand. Although the dehumidifier is primarily designed for
fixed installation on a wall, behind a wall or on the floor, there are applications that require a mobile
application. This is achieved using a mobile stand. This is supplied as a metal construction on 4 fully
swivel castors, the front two of which have brake protection.
The functions and operation of the remote humidistat are described in a separate
enclosed manual.
EL. HEATING POWER SUPPLY
230V/50Hz/1f
Kábel: 3x2.5mm2 CYSY
Príkon: 2kW (DRY300/400), 3kW (DRY500)
Istič:
16A
Black box from the SIDE of the
electrobox
MAIN ELECTRICAL CONNECTION OF THE
DEHUMIDIFIER
230V/50Hz/1f
Cable: 3x 2.5mm2 CYSY
Breaker: 16A type C
Circuit breaker: 30mA
Summary of Contents for DRY 300
Page 46: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 6...
Page 47: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 7...
Page 48: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 4 8...
Page 50: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 0...
Page 51: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 1...
Page 53: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 3...
Page 54: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 4...
Page 55: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 5...
Page 58: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 5 8...
Page 63: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 3...
Page 64: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 4...
Page 65: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 5 Notes...
Page 66: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 6 Notes...
Page 67: ...Installation and user manual D R Y 3 0 0 4 0 0 5 0 0 M e t a l S i l v e r V01 2022 6 7 Notes...