![Micronor MR340-1 Instruction Manual Download Page 56](http://html1.mh-extra.com/html/micronor/mr340-1/mr340-1_instruction-manual_1788066056.webp)
MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 56 of 74
Position Sensor Failures
#
Description
S Remedy
How Cleared
Announced
770 Sensor Disconnect
Detect low optical power
3
Check Fiber Optic
connection to the
sensor. Initiate a new
Sensor pairing.
self clear
when
restored.
Blink 3x
+
code
771 Sensor Low Power
The fiber is connected
however not enough power is
being received for reliable
operation.
2
this error occurs due
to contaminated
connectors. Or long
link lengths in excess
of 1.5km. Check your
fiber optic link. The
one way loss should
be less than 5dB.
self clear
examine error
counter for a
history of this
error.
Blink 2x
+
code
772 Receiver gets excessive optical
power
2
If this occurs the
VCSEL optical power
needs to be reduced.
This is accomplished
using ZAPPY®
software.
An optical attenuator
could also be inserted
into the fiber optic
line.
self clear
examine error
counter for a
history of this
error.
Blink 1x
once
773 Calibration Operation
3
This is not an error!
Indicats number of
automatic calibration
cycles have been
performed.
Self clear
none