![Micronor MR340-1 Instruction Manual Download Page 49](http://html1.mh-extra.com/html/micronor/mr340-1/mr340-1_instruction-manual_1788066049.webp)
MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 49 of 74
Counter Reset (Register 0x209)
Register Address: 0x209
The internal Position Counter will be preset to this pre-programmed value whenever the
External Hardware Reset input goes from logic 0 to logic 1.
Sometimes this function is also called “homing”
The value is 32bit signed.
MODBUS commands:
Quadrature Edge Multiplier (Register 0x211)
Register Address: 0x211
The internal position counter can be set to advance with each edge on the channel A signals
x2 or advance on all transitions x4. If an encoder has a resolution of 512ppr then a total of 512
x 4 = 2048 counts are available.
Modes
Description
0
X2 counting
1
X4 counting
Be sure to set the output scaling according to the multiplier selected.
Address Register Description
Access
0x209
2
Reset Value
Read /
Write