![Micronor MR340-1 Instruction Manual Download Page 40](http://html1.mh-extra.com/html/micronor/mr340-1/mr340-1_instruction-manual_1788066040.webp)
MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 40 of 74
4.3
Detailed Description of Each Function
This section describes the physical outputs from the encoder monitoring circuit.
Counter (Register 0x001)
Register Address: 0x001
Register Count: 2
This is an internal summing counter that keeps accurate track of the full number of quadrature
cycles and the multiplier as applied to in register 0x211.
The counter is relative to a given starting position. The user may reset or preset the counter to
any value within a full 32 bit range.
Range is:
signed 32bit
The (-) sign bit indicates that the encoder is turning Counter Clockwise CCW (looking at the
encoder from the shaft end)
The encoder Counter is volatile and will be reset once electrical power is lost.
MODBUS commands:
Speed /RPM output (Register 0x003)
Register Address: 0x003
Register Count: 2
Speed is calculated based on measuring the time for one quadrature cycle period. Measuring
the period provides very accurate yet fast update rates at slow encoder speeds. The update
rate is always 1ms.
Address Register Description
Access
0x001
2
Encoder Count
Read / Write