MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 11 of 74
Be sure to use proper fiber optic cleaming tools and procedures such as the Micronor
MR321C Cleaning Kit. Improper tools and/or processes may damage or contaminate the
optical interface.
3.2
Mounting the MR340-1 Controller Module
The controller unit mounts on standard 35mm DIN rail or it can be screw mounted to a wall or
cabinet. For DIN rail mounting, insert clip to the unit and then clip onto DIN rail by bending
the clip tabs toward the enclosure. When screw mounting, remove clip from enclosure and
use screws to affix clip to the wall and then clip enclosure onto the plastic clip. Both mounting
schemes are shown below in Figure 3 and Figure 4.
Figure 5. Mounting Controller to 35mm DIN Rail
Figure 6. Mounting Controller to Wall Using Screws