3.7.2
Device Setup
Enter Device Setup menu to configure three main settings of IP cameras,
<Image>, <Video Format> and <Motion>.
Image
Users can configure the image settings of the IP camera. The image settings
include image adjustment, noise reduction, white balance, etc. When users
are adjusting image configuration, users can watch the viewing window at the
right to check the change of image setting in the mean time.
Video Format
In <Video Format> tab, users can configure the settings of video format. The
video format settings include video resolution, video rotate, H.264 profile and
CBR/VBR mode. Besides, users can also set factory default or reboot the IP
camera. Model ID and firmware version can be checked in this tab.
Motion
Users can setup the configuration of motion detection in this tab. Motion
detection settings include sampling, detection level, sensitivity, time interval
and motion window. The following is the description of each item.
Sampling:
This item is used to examine the differences between two frames. Users can
configure the interval of sampling pixel. For instance, if users set the interval
as 5. IP camera system will take one sampling pixel from every 5 pixels of
each row and each column in detection area. The alarm will be triggered
when differences are detected.
Detection Level:
Users can configure detection level for each sampling pixel. Detection level is
how much the dome camera can accept the differences between two
sampling pixels. The smaller the value is, the lower the detection level.
Sensitivity:
This item is used to set the detection sensitivity. A greater value indicates
higher sensitive motion detection.