Manual
Corvus-eco
Starting up
17
Motor connection
Axes designation and assignment
Motor connectors are designated as Axis-1, Axis-2, Axis-3.
They consequental were not labeled as X-Y-Z because this
assignment is determined by the application.
The controller is equipped with two axes by default.
Axis-3 is optional available.
Motor types
Corvus-eco supports 2-Phase DC stepping motors with
step angle 0.9 or 1.8°. Maximum phase current = 1.5A
We recommend Hybrid motors. This motors have 200 rotor
teeth and rotate at 1.80 step angles. Other hybrid motors are
available in 0.9ºand 3.6º step angle configurations. Because
they exhibit high static and dynamic torque and run at very
high step rates, hybrid motors are used in a wide variety of in-
dustrial applications.
Figure 1: Corvus-eco motor connectors
5
1
9
6
5
1
9
6
5
1
9
6
5
1
9
6
5
1
9
6
5
1
9
6
5
1
9
6
C
Joystick
Motor Axis-2
RS-232 / Host
Encoder Axis-2
Encoder Axis-3
Encoder Axis-1
S
Motor Axis-1
USB
Motor Axis-3
RS-232 / Service
Input / Output
C
C
S
S
Cycle
Summary of Contents for Corvus ECO
Page 1: ...Version 1 0 Manual Corvus eco high resolution positioning controller...
Page 5: ...Manual Corvus eco Content 5...
Page 8: ...Chapter 1 Manual Corvus eco Introduction 8 Introduction...
Page 13: ...Chapter 2 Manual Corvus eco Starting up 13 Starting up...
Page 42: ...Manual Corvus eco Starting up 42...
Page 43: ...Chapter 3 Manual Corvus eco Functions 43 Functions...
Page 67: ...Chapter 4 Manual Corvus eco Technical data 67 Technical data...
Page 70: ...Manual Corvus eco Technical data 70 Layout and dimensions...
Page 71: ...Chapter 5 Manual Corvus eco Releasing options 71 Releasing options...
Page 77: ...Manual Corvus Releasing options 77...
Page 80: ...Manual Corvus Releasing options 80...
Page 81: ...Chapter 6 Manual Corvus eco Firmware update 81 Firmware update...
Page 83: ...Manual Corvus Firmware update 83 Update Tool...
Page 84: ...Manual Corvus Firmware update 84...
Page 85: ...Chapter 7 Manual Corvus eco Connectors 85 Connectors...