Manufacturer-specific parameter numbers
Page 61
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
10.5.3
PNU 1102: Current Actual Value
This parameter is used to read the actual current value. When this value is returned, it is referred to
the rated motor current.
PNU
1102
Subindex
0
Name
Current Actual Value
Data type
INT32
Access
ro
Unit
Parts per thousand with regard to the rated motor current
Value range
-
Default value
-
10.5.4
PNU 1140: Digital Outputs
The digital outputs can be set via the parameter
digital outputs
. It has to be kept in mind that a
delay of up to 10 ms may occur between sending the command and a real reaction of the digital
output. The time the outputs are really set can be seen by rereading the parameter.
PNU
1140
Subindex
0
Name
Digital Outputs
Data type
UINT32
Access
rw
Unit
-
Value range
-
Default value
0
Bit
Value
Description
0
00000001h
holding brake (read only)
0...15
reserved
16
00010000h
controller ready for operation (read only)
17,18
00060000h
DOUT1, DOUT2
10.5.5
PNU 1141: Digital Inputs
The parameter is used to read the state of the digital inputs. The available digital inputs depend on the
parameterisation of the servo positioning controller.