Page 82
Function and data blocks for SIEMENS S7
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
13.2.4.2 Reception telegram of the positioning example project
In this case, reception telegram 0 at the servo positioning controller end has to be configured. The
following screenshot shows the necessary parameterisation of the reception telegram for the example
project. An additional diagnostic information is displayed above the
button „Change entry“ if a
communication could have been established between Master and Slave. The really configured length
of the telegram from Master to Slave is displayed.
The following table describes the telegram structure:
Address Content (parameter number)
Description
0
Identifier (= 0xE0)
Fixed identifier
1
8-bit placeholder (PNU 2010 0)
Free
2
Control word 1 (PNU 967 0)
Control word for device control, has to be under this
address
4
Target position (PNU 1001 0)
Target position, indication with the physical unit set for
PROFIBUS
8
Profile velocity (PNU 1001 1)
Profile velocity during positioning, indication with the
physical speed unit set for PROFIBUS
12
Accelerations (PNU 1001 5)
Combination of the values for acceleration and
deceleration, indication with the physical unit set for
PROFIBUS
The total length of this telegram is 16 bytes. When the slave is integrated into the hardware
configuration of the master, the module:
8 Words Output
has to be selected for the output data and connected to one of the ports.