Manufacturer-specific parameter numbers
Page 59
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
Access
rw
Unit
ms
Value range
0...10000
Default value
2000
Subindex
1
Name
iit Ratio Motor
Data type
UINT16
Access
ro
Unit
Promille
Value range
-
Default value
-
10.4.4
PNU 1350: Enable Logic
The parameter
enable_logic
gibt an wie die Reglerfreigabe erfolgen soll.
For safety reasons this is done automatically after activation of CANopen (also after a reset).
PNU
1350
Subindex
0
Name
Enable Logic
Data type
UINT16
Access
rw
Unit
-
Value range
0...3
Default value
0
Value
Description
0
Controller enable via digital input DIN 9
1
Controller enable via digital input DIN 9 + RS232
2
Controller enable via digital input DIN 9 + CAN
3
Controller enable via digital input DIN 9 + Profibus