PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
The example telegram in Figure 6.1 transmits the following parameters:
Address Content (parameter number)
Description
0
Identifier (= 0xE0)
Fixed identifier
1
8-bit placeholder (PNU 2010 0)
free
2
Control Word 1 (PNU 967 0)
Control word for device control, has to be under this
address
4
Target position (PNU 1001 0)
Target position, indication with the physical unit of a
position set for PROFIBUS
8
Profile velocity (PNU 1001 1)
Profile velocity during positioning, indication with the
physical speed unit set for PROFIBUS
12
Acceleration (PNU 1001 5)
Combination of the values for acceleration and
deceleration, indication with physical unit for
acceleration set for PROFIBUS
Detailed information on parameter numbers can be found in
chapters 9 Device control,
10 Manufacturer-specific parameter numbers
12 Profile-specific parameter numbers
6.3
Response telegrams
The firmware of the servo positioning controller DIS-2 48/10 FB supports 2 response telegrams.
The necessary parameter numbers have to be entered for every response telegram. They include the
information concerning the meaning of the data in the telegram. In the case of reception telegrams
0..2, a so-called status word is entered at address 2 (length: 2 bytes). This consistent convention
facilitates the creation of applications and the use of the Metronix example projects for SIEMENS
SIMATIC S7. The other entries can be chosen as desired from the object directory of the parameter
numbers. The only thing that has to be considered is whether they are suitable. It is, for instance, not
possible to enter write-only parameters into response telegrams.
Figure 6.2 shows the example of response telegram 0 (positioning mode). The entries can be
highlighted and changed directly or deleted successively starting with the last entry. When an entry is
highlighted, an additional field is displayed into which the parameter number can be entered. New
telegram entries are added to the end. An additional diagnostic information is displayed above the
button „Change entry“ if a communication could have been established between Master and Slave.
The really configured length of the telegram from Master to Slave is displayed.