MI 3394 CE MultiTesterXA
Single
tests
31
4.1.11 Power
Figure 4.37: Power measurement menu
Test results / sub-results
P ............... Active power
S ............... Apparent power
Q ............... Reactive power
PF ............. Power factor
THDu ........ Total harmonic distortion – voltage
THDi ......... Total harmonic distortion – current
Cos
Φ
....... cosinus
Φ
I ................. Load current
U ............... Voltage
Test parameters
Duration
Duration [Off, 2 s ... 180 s]
Output connections
[Socket L–N]
Test limits
H Limit (P)
H limit [Off, 10 W ... 3.50 kW ]
L Limit (P)
L limit [Off, 10 W ... 3.50 kW]
Test circuit
Figure 4.38: Measurement of Power