58 - 58 021537/06/10
10 Command and description
Command AA
T <id>AA<para5> Functions for PIN 1
Access: User mode
Description: Sets the mode for PIN 1. Values for this parameter can only be changed when the
ULTRASONIC runs in half duplex mode (see Command DM). For the signal line PIN1
the following functions can be specified:
Parameter description:
0: Analog input signal is not used. Full duplex mode is possible
(see Command DM)
1: PIN1 is used as analog input. The analog voltage value at PIN1 is read in
cyclically by the system and digital conversion performed. The analog output
value for WV is switched off (see Command AN).
With a maximum input voltage of 10.0V the digital value output is 65536
(16bit) with a resolution of 152ppm.
The prerequisite for this mode is half duplex mode (see Command DM)
2: Self test of analog wind velocity output
In this state the analog output signal of the wind velocity is read back via the
analog input signal. The prerequisite is that the analog wind velocity output is
switched as a voltage output.
(see Command AN)
PIN1 must not be connected externally. The analog values are output by the
ULTRASONIC, and are re-imported. The analog voltage value at WV/RXD-
undergoes digital conversion cyclically and is read in by the system.
The digital value read-in can be output via the user-defined telegram (see
7.4.5).
The prerequisite for this mode is half duplex mode (see Command DM)
3: Analog output of wind velocity in azimuth. Is output when AN != 2, see
Command AN
4: Input used as SONIC ID (Bit 0). If the mode is selected in which the
ULTRASONIC is to receive its ID via the external lines, this PIN must be
configured as follows: 00AA00004. (see also Command XI)
When using AA, AB and AC the parameter AN must not be switched to two!!! See also
Command AN.
Range of values: 00.. 4
Initial value: 0
Command AB
T <id>AB<para5> Functions for PIN 4
Access: User mode
Description: Sets the mode for PIN4. The values for this parameter can only be changed when the
ULTRASONIC runs in half duplex mode (see Command DM). For the signal line PIN4
the following functions can be specified:
Parameter description:
0: Signal is not used. Full duplex mode is possible (see Command DM)
1: PIN4 is used as analog input. The analog voltage value at
PIN4 is read in cyclically by the system and digital conversion performed. The
analog output value for WD is switched off (see Command AN)
The prerequisite for this mode is half duplex mode (see Command DM)