17 - 17 021537/06/10
3.5 Electrical Installation for Ultrasonic Anemometer with Screwed Cable Gland
The ultrasonic anemometer is equipped with a fix-connected cable by means of a screwed cable
gland. The cable end is open. The core ends are marked by means of pin numbers on cable
marking rings.
3.5.1 Cable Pin Assignment (Examples of function)
Remark:
- For exact allocation of function please refer to supplement “Factory Settings”
- The pins 1 – 6 (incl.) are galvanically isolated from the supply voltage and from
housing.
•
Cable assignment:
Analogue outputs, serial interface halve-duplex
Pin
Colour Code
Assignment
Function
1
white
WG
Analogue output wind speed
2
green
TXD- / RXD-
Serial interface
3
black 1
ADIO
Heating control
4
brown
WR
Analogue output wind direction
5
yellow
TXD+ / RXD+
Serial interface
6
black 2
AGND
Ground for analogue output
and serial interface
7
black 3
AC/DC
Supply, reverse-polarity protected
8
black 4
AC/DC
Supply, reverse-polarity protected
green / yellow
shield