Rev. 1.00
- 42 -
Metapace T-2
<Function 167> GS ( k pL pH cn fn n (fn=67)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS
( k pL
pH
cn
fn n
Hex 1D
28
6B
03
00
31
43
n
Decimal 29 40 107 3 0 49 67 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=67
1
≤
n
≤
8
n=3
Specifies the size of a module of QR Code symbol.
▪
Settings of this function affect the processing of Functions 181 and 182.
▪
The setting unit differs, depending on the printer models.
▪
Settings of this function are effective until ESC @ is executed, the printer
is reset, or the power is turned off.
▪
n = width of a module = height of a module. (Because the QR Code
modules are square.)
<Function 169> GS ( k pL pH cn fn n (fn=69)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS
( k pL
pH
cn
fn n
Hex 1D
28
6B
03
00
31
45
n
Decimal 29 40 107 3 0 49 69 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=69
48
≤
n
≤
51
n=48
Specifies the error correction level of QR Code.
n
Function
Recovery Capacity % (approx.)
48 Specify Error correction level L
7
49 Specify Error correction level M
15
50 Specify Error correction level Q
25
51 Specify Error correction level H
30
▪
Settings of this function affect the processing of Functions 181 and 182.
▪
QR Code employs Reed-Solomon error correction to generate a series of
error correction code words.
▪
Settings of this function are effective until ESC @ is executed, the printer
is reset, or the power is turned off.
<Function 180> GS ( k pL pH cn fn m d1...dk (fn=80)
[Format]
[Range]
[Description]
ASCII GS ( k pL
pH
cn fn m
d1...dk
Hex
1D 28 6B pL pH 31 50 30 d1...dk
Decimal 29 40 107
pL pH 49 80 48 d1...dk
4
≤
(pL + pH x 256)
≤
7092 (0
≤
pL
≤
255, 0
≤
pH
≤
27)
cn=49
fn=80
m=48
0
≤
d
≤
255
k = (pL + pH x 256) – 3
Stores the QR Code symbol data (d1...dk) in the symbol save area.