Rev. 1.00
- 49 -
Metapace T-2
GS ^ r t m
[Name]
[Format]
[Range]
[Description]
Execute macro.
ASCII GS ^ r t m
Hex 1D
5E
r t m
Decimal 29 94
r
t
m
0
≤
r
≤
255
0
≤
t
≤
255
m=0, 1
▪
Executes a macro.
- r specifies the number of times to execute the macro.
- t specifies the waiting time for executing the macro.
- m specifies macro executing mode from the table below.
m
Function
0
Executes the macro r times at the interval specified by t.
1
After waiting for the time specified by t, the PAPER OUT LED flashes to indicate
that the FEED button must be pressed. After the button is pressed, the macro is
executed once. This operation is then repeated r times.
GS a n
[Name]
[Format]
[Range]
[Default]
[Description]
Enable/Disable Automatic Status Back (ASB).
ASCII GS a n
Hex 1D
61
n
Decimal
29 97 n
0
≤
n
≤
255
n=0 when memory switch 1-3 is Off.
n=2 when memory switch 1-3 is On.
▪
Specifies the status items for ASB (Automatic Status Back).
Bit Off/On Hex Decimal
Function
Off
00
0
Drawer kick-out connector pin 3 disable.
0
On
01
1
Drawer kick-out connector pin 3 enable.
Off
00
0
Online/Offline status disabled.
1
On
02
2
Online/Offline status enabled.
Off
00
0
Error status disabled.
2
On
04
4
Error status enabled.
Off
00
0
Paper roll sensor status disabled.
3
On
08
8
Paper roll sensor status enabled.
4 Off 00 0 Reserved.
5 Off 00 0 Reserved.
Off
00
0
Panel button status disabled.
6
On
40
64
Panel button status enabled.
7 Off 00 0 Reserved.