Rev. 1.00
- 8 -
Metapace T-2
DLE DC4 fn m t (fn=1)
[Name]
[Format]
[Range]
[Description]
Generate pulse in real-time.
ASCII DLE DC4 fn m t
Hex 10
14
1 m t
Decimal 16 20
1
m
t
fn=1
0
≤
m
≤
8
1
≤
t
≤
8
▪
Outputs the pulse specified by t in real-time to the connector pin specified
by m as follows :
n
Connector pin
0
Drawer kick-out connector pin 2.
1
Drawer kick-out connector pin 5.
- The pulse ON time or OFF time is set to [t x 100 ms].
▪
Specify n=1 or 2 after removing the cause of the error.
▪
If print data includes a character string with this command, the printer
performs the command. User must consider this.
- For example : Bit image data accidentally might include a data string
with this command.
▪
Do not embed this command within another command.
- For example : Bit image data might include this command.
▪
This command is ignored in the following states :
- During transmission of block data.
- During driving of drawer kick-out.
- When an error has occurred.
DLE DC4 fn a b (fn=2)
[Name]
[Format]
[Range]
[Description]
Execute power-off sequence.
ASCII DLE DC4 fn a b
Hex 10
14
fn a b
Decimal
16 20 fn a b
fn=2
a=1
b=8
▪
Executes the printer power-off sequence.
- Stores the values of the maintenance counter.
- Transmits the following power-off status ( NUL).
Power off status
Hex
Decimal
Amount of data
Header
3B H
59
1 byte
Status
30 H
48
1 byte
NUL
00 H
0