38
OPERATING MANUAL - Z587 BALER
Maintenance and adjustment
This symbol marks the lubrication points:
Table 5. Lubrication points.
Manual chain lubrication (every 10 operating hours)
If the automatic chain lubrication system accessory is not equipped,
relubricate manually with special chain preservative lubricant grease.
Net wrapper chain lubrication
The net wrapper chain is not lubricated by the central lubrication
system (if equipped). Relubricate by hand as follows: open the left-hand
side guard and relubricate the net wrapper chain.
Table 6. Net wrapper chain lubrication.
5.13. AUTOMATIC CHAIN LUBRICATION SYSTEM
The baler may be optionally equipped with the automatic chain
lubrication system.
The system is actuated each time the rear chamber is closed.
The oil dosage is adjusted by setting the piston "P" on the small
pump.
If the oil flow is incorrect, set the distance "D" by changing the small
pump piston "P" stroke.
1. Open the left-hand safety guard.
2. Loosen both hex bolts "A".
3. Slide the pump along the slot (to change the distance "D") and
increase or reduce the piston P"" stroke as required.
•
Increasing the piston "P" stroke increases the oil volume fed to the
automatic chain lubrication circuit.