12.3
Changing the air filters
12.3.1 Removing the cover from the ventilation unit
► Using both thumbs, press the two
latches (item 1 in Fig. 18) on the
bottom of the ventilation unit. The unit
cover will come away.
► At the same time, push your index
fingers into the gap between the unit
cover and housing, and lift the unit
cover up and away from the housing.
► Switch the ventilation unit off at
the mains switch (see Fig. 13 on
page 23). On ventilation units with
the M-WRG-II O/NOF option, power
to the unit must be switched off
using the building’s miniature circuit
breaker.
12.3.2 Removing the extract air filter
► Turn the filter ring (item 1 in Fig. 19)
using the hand grip (item 2 in Fig. 19)
anti-clockwise until the filter ring is
released from the retainers.
► Pull the filter ring together with the
extract air filter (item 3 in Fig. 19) out
of the ventilation unit.
► Detach the extract air filter from the
filter ring.
► Clean the filter ring with a damp cloth
if it is dirty (see section 13).
Fig. 18: Removing the cover from the ventilation unit
1
1
Fig. 19: Removing the extract air filter
1
2
3