Mellanox Technologies
35
Figure 29: PS Unit Pulled Out
To insert a power supply unit:
Step 1.
Make sure the mating connector of the new unit is free of any dirt and/or obstacles.
Do not attempt to insert a power supply unit with a power cord connected to it.
Step 2.
Insert the power supply unit by sliding it into the opening until a slight resistance is felt.
Step 3.
Continue pressing the power supply unit until it seats completely. The latch will snap into
place, confirming the proper installation.
Step 4.
Insert the power cord into the supply connector.
Step 5.
Insert the other end of the power cord into an outlet of the correct voltage.
The green power supply unit indicator should light. If not, repeat the whole procedure
to extract the power supply unit and re-insert it.
2.9.2
Fans
The system can fully operate if one fan FRU is dysfunctional or missing. Failure of more than
one fan is not supported..
Make sure that the fans have the air flow that matches the model number. An air flow
opposite to the system design will cause the system to operate at a higher (less than
optimal) temperature.
For power supply unit air flow direction, refer to Section 2.2 on page 8
Summary of Contents for SX6710
Page 1: ...Mellanox SX67X0 1U Switch Systems Hardware User Manual Rev 1 4 www mellanox com...
Page 19: ...Mellanox Technologies 13 Figure 10 BBU Insertion Left and Extraction Right...
Page 68: ...Mellanox Technologies 62 2 3 4 5 6 7 8...
Page 69: ...Mellanox Technologies 63 9 10 11 12 13 14 15...
Page 70: ...Mellanox Technologies 64 16 17 18 19 20 21 WEEE...
Page 72: ...Mellanox Technologies 66 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 73: ...Mellanox Technologies 67 10 11 InfiniBand 12 13 14 15 16 InfiniBand...
Page 76: ...Mellanox Technologies 70 27 China CCC Warning Statement...
Page 91: ...Mellanox Technologies 85 7 8 9 10 11 InfiniBand InfiniBand 12 13...