Table 11 - Configuration Wizard Session
Wizard Session Display
Comments
Mellanox configuration wizard
Do you want to use the wizard
for initial configuration? yes
You must perform this configuration the first time you operate the
system or after resetting the system. Type ‘y’ and then press
<Enter>.
Step 1: Hostname? [switch ]
If you wish to accept the default hostname, press <Enter>. Other-
wise, type a different hostname and press <Enter>.
Step 2: Use DHCP on mgmt0
interface? [no] yes
Perform this step to obtain an IP address for the system. (mgmt0 is
the management port of the system).
If you wish the DHCP server to assign the IP address, type ‘yes’
and press <Enter>.
If you type ‘no’ (no DHCP), then you will be asked whether you
wish to use the ‘zeroconf’ configuration or not.
If you enter ‘no’ (no Zeroconf), you must enter a
static
IP, and the
session will continue.
Step 3: Enable IPv6? [yes]
The management interface will be able to use IPv6 addresses.
If you enter "no" (no IPv6), you will automatically be referred to
Step 6.
Step 4: Enable IPv6 auto-config
(SLAAC) on mgmt0 interface?
[no]
This turns on auto-configuration of the IPv6 addresses. This is
unsuitable for DHCPv6.
Step 5: Enable DHCPv6 on
mgmt0 interface? [no]
To enable DHCPv6 on the MGMT0 interface.
Step 6: Admin password (Press
<Enter> to leave unchanged)?
<new_password>
Step 6: Confirm admin pass-
word? <new_password>
To avoid illegal access to the machine, please type a password and
then press <Enter>. Then confirm the password by re-entering it.
Note that password characters are
not
printed.
You have entered the following
information:
<A summary of the configura-
tion is now displayed.>
To change an answer, enter the
step number to return to or hit
<enter> to save changes and exit.
Choice: <Enter>
Configuration changes saved.
The wizard displays a summary of your choices and then asks you
to confirm the choices or to re-edit them.
Either press <Enter> to save changes and exit, or enter the configu-
ration step number that you wish to return to.
Note:
To re-run the configuration wizard, run the command “configura-
tion jump-start” in Config mode.
Mellanox Technologies
31
Summary of Contents for SX6710
Page 1: ...Mellanox SX67X0 1U Switch Systems Hardware User Manual Rev 1 4 www mellanox com...
Page 19: ...Mellanox Technologies 13 Figure 10 BBU Insertion Left and Extraction Right...
Page 68: ...Mellanox Technologies 62 2 3 4 5 6 7 8...
Page 69: ...Mellanox Technologies 63 9 10 11 12 13 14 15...
Page 70: ...Mellanox Technologies 64 16 17 18 19 20 21 WEEE...
Page 72: ...Mellanox Technologies 66 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 73: ...Mellanox Technologies 67 10 11 InfiniBand 12 13 14 15 16 InfiniBand...
Page 76: ...Mellanox Technologies 70 27 China CCC Warning Statement...
Page 91: ...Mellanox Technologies 85 7 8 9 10 11 InfiniBand InfiniBand 12 13...