Planning the system’s placement in the rack
Before mounting the system to the rack, select the way you wish to place the system. Pay atten-
tion to the airflow within the rack cooling, connector and cabling options.
While planning how to place the system, review the following points:
• Make sure the system air flow is compatible with your installation selection. It is
important to keep the airflow within the rack in the same direction.
• In case there are cables that cannot bend within the rack or in case more space is needed
for cable bending radius, it is possible to recess the connector side or the FRU side by
3” or 4” (7.62 or 10.16cm) by optional placement of the system’s rails.
• The FRU side is extractable. Mounting the sliding rail inverted to the system will allow
you to slide the FRU side of the system, in and out.
Step 1.
Install 10 cage nuts into the desired 1U slot of the rack: 4 cage nuts in the non-extractable side
and 6 cage nuts in the extractable side.
Step 2.
Mount both of the outer rails (C+D) into the rack (as illustrated in Figure 19), and use 8 stan-
dard pan-head screws (E) to fix them to the rack. Do not tighten the screws yet.
Step 3.
If cable accommodation is required, rout the power cable and/or Eth cable through either of the
outer rails.
Step 4.
Secure the switch to the left and right inner rails (A+B), by gently pushing the switch chassis’
pins through the slider key holes, until locking occurs.
Step 5.
Secure the chassis in the inner rails screwing the 2 flat head Phillips screws (F) in the desig-
nated points.
Figure 19: Mounting the Outer Rails into the Rack
Summary of Contents for SX6710
Page 1: ...Mellanox SX67X0 1U Switch Systems Hardware User Manual Rev 1 4 www mellanox com...
Page 19: ...Mellanox Technologies 13 Figure 10 BBU Insertion Left and Extraction Right...
Page 68: ...Mellanox Technologies 62 2 3 4 5 6 7 8...
Page 69: ...Mellanox Technologies 63 9 10 11 12 13 14 15...
Page 70: ...Mellanox Technologies 64 16 17 18 19 20 21 WEEE...
Page 72: ...Mellanox Technologies 66 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 73: ...Mellanox Technologies 67 10 11 InfiniBand 12 13 14 15 16 InfiniBand...
Page 76: ...Mellanox Technologies 70 27 China CCC Warning Statement...
Page 91: ...Mellanox Technologies 85 7 8 9 10 11 InfiniBand InfiniBand 12 13...