Troubleshooting
Mellanox Technologies
48
5
Troubleshooting
5.1
Troubleshooting Instructions
Table 21 - Troubleshooting
Problem
Indicator
Symptoms
Corrective Measures
LEDs
System Status LED is
blinking for more than 5
minutes
This state means that the MLNX-OS software did not
boot properly and only firmware is running.
To overcome it, connect to the system via the console
port, and check the software status. You might need to
contact an FAE if the MLNX-OS software did not load
properly
System Status LED is red
This state can indicate a number of problems:
•
Critical system fault (CPU error, bad firmware)
•
Over Temperature
To overcome it:
•
Check Environmental conditions (room temperature)
Fan Status LED is red
This state is indicative of a problem with the FAN.
•
Check that the FAN is fully inserted and nothing blocks
the airflow.
•
Replace the FAN FRU if needed.
PSU Status LED is red
This state is indicative of a problem with the PSU.
•
Check/replace the power cable.
•
Replace the PSU if needed.
The activity LED does not
light up (InfiniBand):
Make sure that there is an SM running in the fabric.
Summary of Contents for SX6710
Page 1: ...Mellanox SX67X0 1U Switch Systems Hardware User Manual Rev 1 4 www mellanox com...
Page 19: ...Mellanox Technologies 13 Figure 10 BBU Insertion Left and Extraction Right...
Page 68: ...Mellanox Technologies 62 2 3 4 5 6 7 8...
Page 69: ...Mellanox Technologies 63 9 10 11 12 13 14 15...
Page 70: ...Mellanox Technologies 64 16 17 18 19 20 21 WEEE...
Page 72: ...Mellanox Technologies 66 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 73: ...Mellanox Technologies 67 10 11 InfiniBand 12 13 14 15 16 InfiniBand...
Page 76: ...Mellanox Technologies 70 27 China CCC Warning Statement...
Page 91: ...Mellanox Technologies 85 7 8 9 10 11 InfiniBand InfiniBand 12 13...