Installation
Mellanox Technologies
28
2.7
Initial Power On
The system’s input voltage is auto-adjusting for 100 - 240VAC, 50-60Hz power connections. The
power cords should be standard 3-wire AC power cords including a safety ground and rated for
15A or higher.
Caution: The system platform will automatically power on when AC power is
applied. There is no power system. Check all boards, power supplies, and fan tray
modules for proper insertion before plugging in a power cable.
Step 1.
Plug in the first power cable.
Step 2.
Plug in the second power cable.
Step 3.
Wait for the system upload process.
It may take up to five minutes to turn on the system. If the System Status LED shows
red after five minutes, unplug the system and call your Mellanox representative for
assistance.
Step 4.
Check the System Status LEDs and confirm that all of the LEDs show status lights consistent
with normal operation (initially flashing and then moving to a steady color) as shown in
Figure 27 below. For more information, refer to “LEDs” on page 41.
Figure 27: System Status LEDs 5 Minutes After Power On
Summary of Contents for SX6710
Page 1: ...Mellanox SX67X0 1U Switch Systems Hardware User Manual Rev 1 4 www mellanox com...
Page 19: ...Mellanox Technologies 13 Figure 10 BBU Insertion Left and Extraction Right...
Page 68: ...Mellanox Technologies 62 2 3 4 5 6 7 8...
Page 69: ...Mellanox Technologies 63 9 10 11 12 13 14 15...
Page 70: ...Mellanox Technologies 64 16 17 18 19 20 21 WEEE...
Page 72: ...Mellanox Technologies 66 3 4 5 6 7 8 9 45 C 113 F 8 3 PSU...
Page 73: ...Mellanox Technologies 67 10 11 InfiniBand 12 13 14 15 16 InfiniBand...
Page 76: ...Mellanox Technologies 70 27 China CCC Warning Statement...
Page 91: ...Mellanox Technologies 85 7 8 9 10 11 InfiniBand InfiniBand 12 13...